Intelligent Three-Phase AC Motor Soft Starter (380V/660V, Bypass & Online Series)

Manufactured in China by Yongfan Electric (YOF®), an ISO9001 & CCC-certified factory and global supplier, this intelligent motor soft starter combines microprocessor SCR thyristor drive, fuzzy PID closed-loop control, and LCD keypad operation for 380V±15% (220V/660V optional) 50/60Hz three-phase squirrel-cage asynchronous motors. Available in Bypass (Type A/B), Online (Type C/D), and Built-In Bypass (Type E) configurations compliant with GB14048.6 / IEC60947-2-2, it delivers smooth soft start, soft stop, light-load energy saving, and 12 built-in motor protection functions for industrial and commercial water pumps, fans, compressors, and crushers. We support bulk wholesale and custom OEM/ODM cabinet projects—contact us today for the full specification datasheet, flexible MOQ, and a direct factory quote.
  • Detailed Description

Independently developed and manufactured in China by Yongfan Electric Co., Ltd. (YOF®)—an ISO9001 & CCC-certified manufacturer, factory, and global B2B supplier—the Intelligent Soft Starter uses a high-performance microprocessor as its control core. It integrates SCR (thyristor) power drive technology, hardware and software protection, a menu-driven LCD screen, keypad operation, torque control, and a fuzzy PID closed-loop control algorithm into an advanced intelligent motor starting device.

Combining smooth motor soft start, soft stop, light-load energy saving, and comprehensive motor protection functions with stable performance, this series is widely deployed across industrial and commercial transmission equipment, ventilation fans, water pumps, compressors, and heavy loads. All units strictly comply with national and international standards GB14048.6-2008 (and IEC60947-2-2: 2002) and are available for bulk wholesale, custom OEM, and ODM engineering projects.

Five Structural Categories (Identical technical parameters, differing only in structural configuration):
Type A
Bypass Soft Starter
External bypass contactor type
Type B
Bypass Soft Start Cabinet
Complete enclosed cabinet assembly
Type C
Online Soft Starter
Continuous online operation without bypass
Type D
Online Soft Start Cabinet
Enclosed online cabinet system
Type E
Built-In Bypass Soft Starter
Integrated internal bypass contactor

Model Description & Nomenclature

□□□
Product Code
-
55
Power Rating (kW)
A
Structural Type (A/B/C/D/E)
-
T4
Power Phase & Voltage
M
Communication Function
Code Segment Designation Specification Details
□□□ Product Code Enterprise/series model identifier
55 Power Rating Applicable motor rated power (e.g., 55kW)
A / B / C / D / E Structural Configuration A: Bypass soft starter  |  B: Bypass soft start cabinet  |  C: Online soft starter  |  D: Online soft start cabinet  |  E: Built-in bypass soft starter
T4 / T6 Power Phase & Voltage T: Three-phase power supply  |  4: 380V  |  6: 660V
M Communication Function Indicates RS485 / serial communication capability

Product Features

1. High-Duty Frequent Start & Stop
Engineered to withstand continuous long-term operation and repeated, frequent motor starting and stopping cycles.
2. Harsh Industrial Environment Tolerance
Operates reliably in demanding environments containing smoke, airborne dust, ash, and sand particles.
3. Wide Operating Voltage Range
Adapts to wide grid voltage fluctuations (380V ± 15%, with 220V and 660V optional), outperforming comparable conventional starters.
4. Clear LCD Display & Intuitive Keypad
Menu-driven screen display makes parameter modification and real-time operating status monitoring clear at a glance.
5. Compact & Lightweight Construction
Weighs less than one-third (1/3) of traditional autotransformer starters, simplifying cabinet integration, field transport, and outdoor installation.

Technical Parameter Specification

Project (Item) Specification
Standards Compliant GB14048.6 / IEC60947-2-2: 2002
Three-Phase Power Voltage (AC) 380V ± 15% (220V and 660V Optional)
Frequency 50 / 60Hz
Applicable Motor Squirrel-cage three-phase asynchronous motor
Start Frequency Full-load motor start: no more than 4 times/hour; no-load or light-load: recommended no more than 10 times/hour
Degree of Protection IP20
Shock Resistance (Impact) Conforms to IEC68-2-27: 15g, 11ms
Seismic / Vibration Capacity Altitude below 3000 meters above sea level, vibration intensity below 0.5g
Ambient Temperature Operating temperature 0~40°C without derating (between +40°C~60°C, derate current by 2% for every 1°C increase) and less than 60°C
Storage Temperature -25°C ~ 70°C
Environment Humidity 93% without condensation or dripping, in compliance with IEC68-2-3
Maximum Operating Altitude Within 1000 meters altitude without derating (above 1000 meters, derate current by 5% for each additional 100 meters)
Cooling Method Natural air cooling
Mounting Orientation (Relative to Vertical) Vertical installation, tilt angle within ±10°

Common Industrial Applications

  • Quarry & Mining Crushers: Motors on stone crushers in quarries and mining sites (coal, copper, phosphorus, titanium, iron ore, etc.).
  • Brick-Making Machinery: Heavy-duty extruder and press motors in brick manufacturing plants.
  • High-Lift Water Pumps: Pipeline pumps, multi-stage pumps, and centrifugal pumps drawing water from rivers and lakes to high-altitude channels.
  • Submersible Sewage Pumps: Municipal and industrial submersible wastewater and drainage pump systems.
  • Tunnel & Mine Ventilation Fans: High-inertia exhaust blowers and ventilation fans in tunnels and underground mines.
  • Water Intake & Delivery Systems: Motors in municipal and agricultural water intake and transmission stations.
  • General Asynchronous Motor Loads: General industrial equipment driven by three-phase squirrel-cage induction motors.

12 Built-In Motor Protection Functions

01. External Fault Input (Instant Stop Terminal): Connects to external dedicated protection relays such as thermal relays.
02. Power-Loss Restart Prevention: Prevents automatic restart when grid power returns after an outage, regardless of control terminal position.
03. Excessive Start-Up Time Protection: Trips for self-protection if the motor fails to complete starting within the set time window.
04. Soft Starter Overheat Protection: Trips within <0.1s at 80°C ± 5°C; resets when temperature drops down to 55°C (minimum).
05. Input Phase Loss Protection: Lag time <3 seconds.
06. Output Phase Loss Protection: Lag time <3 seconds.
07. Three-Phase Unbalance Protection: Lag time <3 seconds (triggers when phase current deviation exceeds 50%).
08. Starting Overload Protection: Trips when starting current continuously exceeds 5× the rated working current of the motor.
09. Running Overload Protection: Inverse-time thermal protection based on the motor rated working current (refer to tripping time curve).
10. Supply Under-Voltage Protection: Trips in <0.5s when supply voltage drops below 50% of limit value; otherwise <3s when below set threshold.
11. Supply Over-Voltage Protection: Trips in <0.5s when supply voltage exceeds 130% of limit value; otherwise <3s when above set threshold.
12. Load Short-Circuit Protection: Lag time < 0.1 s when fault current exceeds 10× the nominal motor current of the soft starter.

Parameter Setting & Description (Menu Codes F0 – FN)

Code Name Predetermined Area (Setting Range) Factory Default Description
F0 Starting voltage 30-80% 30% Effective in voltage ramp mode; in current limit mode, the starting voltage is fixed at 40%
F1 Soft start time 2-60S 16S Invalid in current limit mode
F2 Soft stop time 0-60S 0S Set to 0 for free stop (coast-to-stop); please set to 0 for one-to-two (dual-motor) drive wiring
F3 Interval delay 0-999S 0S Sets the interval time between starts to prevent equipment damage from frequent starting
F4 Programming delay 0-999S 0S Used for programmable relay output delay
F5 Starting limit current 50-500% 280% Effective in current limit mode; in voltage ramp mode, the maximum current limit is 400%
F6 Maximum operating current 50-200% 100% Percentage of the rated current of the motor
F7 Under-voltage protection 40-90% 80% Protection trips when supply voltage falls below the set value
F8 Overvoltage protection 100-140% 120% Protection trips when supply voltage exceeds the set value
F9 Start mode 0-5 1 0: Current limit  |  1: Voltage ramp  |  2: Kickstart + Current limit  |  3: Kickstart + Voltage ramp  |  4: Current ramp (slope)  |  5: Dual closed-loop
FA Output protection allowed 0-4 4 0: Primary  |  1: Light load  |  2: Standard  |  3: Heavy load  |  4: Advanced
FB Operation control method 0-6 1 0: Keypad  |  1: Keypad + External control  |  2: External control  |  3: External control + Communication  |  4: Keypad + External control + Communication  |  5: Keypad + Communication  |  6: Communication  |  7: Start/stop prohibited
FC Parameter modification allowed 0-2 1 Please refer to the manual for details
FD Communication address 0-63 0 Used for multi-unit communication between multiple soft starters and a host computer
FE Programming output 0-19 7 Run relay output (terminals 03, 04) setting
FF Soft stop current limit 20-100% 80% Please refer to the manual for details
FP Motor rated current — Rated value Used to input the nominal rated current of the motor
FU Bypass delay 1-99S 5 Increases the bypass switching delay time
FL Three-phase balance allowed 0-1 1 0: Prohibited  |  1: Permitted
FM Current coefficient 50-150% 100% Decrease coefficient if displayed current is higher than actual; increase if lower
FN Voltage coefficient 50-150% 100% Decrease coefficient if displayed voltage is higher than actual; increase if lower
Operational Remarks & Programming Notes:
  1. Setting code F6 (Maximum operating current) refers to the maximum continuous operating current calculated from the FP motor rated current class; exceeding this value initiates inverse-time thermal overload protection.
  2. In the parameter setting state, if no key is pressed within 2 minutes, the controller automatically exits the setting mode.
  3. Parameters cannot be modified during active soft start or soft stop processes, but can be modified in standby or other operating states.
  4. Pressing and holding the confirm key (YES) while powering on restores all parameters (except FE) to their factory default values.

Working Principle & Soft-Start Characteristic Curves

1. Torque and Current Characteristics of Three-Phase AC Induction Motors

Three-phase AC induction motors are widely used in agriculture, commercial buildings, and industrial plants due to their rugged durability, simple structure, and maintenance-free operation. However, during direct-on-line (DOL) starting, a three-phase AC induction motor draws a severe inrush starting current—typically 6 to 8 times its rated working current (IN)—while generating starting torque and breakdown (pull-out) torque reaching 2 to 4 times its rated torque (MN).

For driven machinery sized according to rated motor torque, direct starting creates severe mechanical shock loads and results in three major engineering drawbacks:

  • Severe Mechanical Stress: High starting torque shocks couplings, belts, gearboxes, and driven transmission mechanisms;
  • Increased Maintenance Costs: Accelerated mechanical wear and water-hammer effects in piping systems raise maintenance downtime and repair costs;
  • Oversized Power Grid Requirement: The upstream transformer and distribution network must be oversized to withstand the 6–8× starting current surge. Deploying a motor soft starter smoothly tailors both starting current and starting torque to match the exact load curve of the equipment.
Figure 1: Direct-On-Line (DOL) Motor Current (I) and Motor Torque (M) vs. Speed (n) Curves
Three-Phase AC Asynchronous Motor Direct Starting Current I and Torque M Characteristic Curves

2. Soft-Start Working Principle (Anti-Parallel Thyristor Phase Control)

Each phase of the soft starter employs two anti-parallel thyristors (SCRs)—one conducting during the positive half-wave and the other during the negative half-wave. Using phase-angle triggering control within a selectable start-up ramp time, the controller continuously increases the effective RMS motor voltage from a selectable initial starting voltage up to the full rated line voltage. Because motor starting current is directly proportional to the applied voltage, the starting current is reduced linearly by the voltage reduction factor. Meanwhile, because motor torque is proportional to the square of the applied voltage, the starting torque decreases quadratically with voltage reduction—eliminating mechanical shock and current surges.

Figure 2: Torque and Current Characteristics of Three-Phase AC Asynchronous Motor During Soft Start
Torque and Current Characteristics of Three-Phase AC Asynchronous Motor When Starting with Soft Starter
① Voltage ramp during soft start
② Regulated starting torque via soft starter
③ Typical load torque curve (e.g., centrifugal pump)
Direct China Factory Wholesale, Custom OEM/ODM & Engineering Support

As a direct China manufacturer and supplier, Yongfan Electric Co., Ltd. (YOF®) supplies ISO9001 & CCC certified intelligent motor soft starters (Bypass Type A/B, Online Type C/D, and Built-In Bypass Type E) for industrial and commercial projects worldwide. Contact our engineering team to request the complete product datasheet, wiring specification manual, flexible MOQ terms, or a competitive factory quote for bulk order and custom OEM/ODM cabinet solutions.

Related products

CHINA · YONGFAN ELECTRIC CO., LTD. (YOF®)

Professional China manufacturer of BK/JBK/JMB/SBK/SG Transformers, Online & Bypass Intelligent Soft Starters & Cabinets, YFX01 Autotransformer Starting Boxes, TND/TNS/SBW/DJW/SJW Voltage Stabilizers, and TDGC2/TSGC2 Contact Voltage Regulators since 2009.

FACTORY CONTACT

Add: Dongfeng Industrial Zone, Liushi Town, Yueqing City, Zhejiang Province, China

Tel: +86-577-27877036 | Fax: +86-577-27877037

Mobile: +86-13968736791 / +86-13868325933

Email: YOF@cnyofan.com

© China · Yongfan Electric Co., Ltd. (YOF®). All Rights Reserved.

online service

Hello, I am the online customer service

X